1T Reverse Osmosis Industrial Commercial Water Treatment Machine Single-Pole Three-Tank Water Purification Treatmen
Production Description
Pretreatment three-tank process flow:
Raw water tank-raw water pump-quartz sand filter-activated carbon
filter-resin softener-security filter-high pressure pump-RO reverse
osmosis system-pure water tank
Parameter Table
Model | Water Making Ability | Inlet Caliber | Effluent Caliber | Blowdown alCer | Size(mm) | Power |
YSRO-0.5T | 0.5m3/h | DN20 | DN20 | DN15 | 1500×600×1500 | 1.3kw |
YSRO-1T | 1m3/h | DN25 | DN25 | DN20 | 1700×600×1500 | 2.1kw |
YSRO-2T | 2m3/h | DN32 | DN25 | DN20 | 2500×1000×1950 | 4.4kw |
YSRO-3T | 3m3/h | DN40 | DN32 | DN25 | 2500×1200×2150 | 4.5kw |
YSRO-5T | 5m3/h | DN50 | DN40 | DN32 | 2500×1350×2150 | 7.0kw |
YSRO-8T | 8m3/h | DN50 | DN50 | DN40 | 3500×1500×2150 | 11kw |
YSRO-10T | 10m3/h | DN50 | DN50 | DN40 | 3500×1600×2300 | 15kw |
Key advantages
The equipment does not need to use a large number of chemical agents and acid and alkali regeneration treatment, so there is no discharge of chemical waste liquid and no environmental pollution.The equipment uses a fully automatic pretreatment system, which can realize unmanned operation.The equipment is equipped with on-line water quality monitoring and control to monitor water quality changes in real time and ensure water quality safety.
Maintance
Shutdown protection of reverse osmosis device
Short-term protection is applicable to the system that has been
shut down for less than 15 days, and the method of low-pressure
flushing every 1 ~ 3 days can be used to protect the reverse
osmosis device.In practice, it is found that when the water
temperature is above 20 ℃, the water in the reverse osmosis device
will stink and deteriorate after 3 days of storage, and a large
number of bacteria will multiply.Therefore, when the water
temperature is higher than 20 ℃, it is recommended to wash at low
pressure once every 2 days or 1 day; when the water temperature is
lower than 20 ℃, it is recommended to wash at low pressure once
every 3 days. After each washing, all inlet and outlet valves on
the reverse osmosis device of the water purification equipment
shall be closed.