Sign In | Join Free | My burrillandco.com
Home > Reverse Osmosis Water Treatment Equipment >

0.5 Tons Reverse Osmosis Water Treatment Equipm Double Stage Reverse Osmosis Filter System For Pure Water Production

Jingte 'er Environmental Protection Engineering Co.,Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap 0.5 Tons Reverse Osmosis Water Treatment Equipm Double Stage Reverse Osmosis Filter System For Pure Water Production from wholesalers
     
    Buy cheap 0.5 Tons Reverse Osmosis Water Treatment Equipm Double Stage Reverse Osmosis Filter System For Pure Water Production from wholesalers
    • Buy cheap 0.5 Tons Reverse Osmosis Water Treatment Equipm Double Stage Reverse Osmosis Filter System For Pure Water Production from wholesalers

    0.5 Tons Reverse Osmosis Water Treatment Equipm Double Stage Reverse Osmosis Filter System For Pure Water Production

    Ask Lasest Price
    Brand Name : HYJB
    Model Number : 0.5 tons double-stage
    Price : negotiable
    Payment Terms : L/C, D/A, D/P, T/T, T/T, Western Union, MoneyGram
    Supply Ability : 200 sets /month
    Delivery Time : 7 days
    • Product Details
    • Company Profile

    0.5 Tons Reverse Osmosis Water Treatment Equipm Double Stage Reverse Osmosis Filter System For Pure Water Production

    0.5 tons of Single-stage reverse osmosis water treatment for Pure Water Production Line


    Product Description


    Single-stage reverse osmosis equipment is also known as a reverse osmosis equipment, that is, our raw water through the pretreatment system, precision filters, and then through a high-pressure pump will be sent to the reverse osmosis device directly to the output of the product water is called single-stage reverse osmosis. The two-stage reverse osmosis equipment is also known as secondary reverse osmosis, the same is also the raw water pressurized to the pretreatment system coarse filtration, and then into the precision filter filtration, and then through a high-pressure pump pressurized to the first level of reverse osmosis system, and then the output of the system of water from the two high-pressure pumps to the second level of pressure to send to the second level of reverse osmosis system, so that the product of the product out of the water known as two-stage reverse osmosis. Today we will focus on single-stage reverse osmosis equipment.


    Parameter Table


    Model
    Water Making Ability
    Inlet Caliber
    Effluent Caliber
    Blowdown alCer
    Size(mm)
    Power
    YSRO-0.5T
    0.5m3/h
    DN20
    DN20
    DN15
    1500×600×1500
    1.3kw
    YSRO-1T
    1m3/h
    DN25
    DN25
    DN20
    1700×600×1500
    2.1kw
    YSRO-2T
    2m3/h
    DN32
    DN25
    DN20
    2500×1000×1950
    4.4kw
    YSRO-3T
    3m3/h
    DN40
    DN32
    DN25
    2500×1200×2150
    4.5kw
    YSRO-5T
    5m3/h
    DN50
    DN40
    DN32
    2500×1350×2150
    7.0kw
    YSRO-8T
    8m3/h
    DN50
    DN50
    DN40
    3500×1500×2150
    11kw
    YSRO-10T
    10m3/h
    DN50
    DN50
    DN40
    3500×1600×2300
    15kw

    Key Advantage


    Components are imported or domestic high-quality products, advanced technology; high degree of integration, reliable quality; high degree of automation, stop immediately in case of failure, with automatic protection; high rate of desalination, up to 99% or more; the use of high-efficiency, low-noise imports of good pressure pumps, to reduce the operating noise; to reduce energy consumption, thereby reducing the operating costs;


    Maintenance


    Before the raw water enters the reverse osmosis equipment, its SDI15 value should always be kept below 5, and the maximum turbidity of the feed water shall not exceed 1.0, which helps to extend the service life of the membrane. The equipment should be designed to prevent the high pressure pump start and stop when the water hammer generated by the impact of reverse osmosis membrane measures. The pure water produced in the first hour after the start of operation should be discharged to ensure that the water quality meets the standard. Regular and reasonable pretreatment to flush the reverse osmosis membrane is an important step to maintain the performance of the equipment. Avoid adding scale inhibitors during low-pressure flushing, but add them during high-pressure operation flushing, and all wastewater and output water generated during flushing must be discharged in a timely manner.


    Product Display


    0.5 Tons Reverse Osmosis Water Treatment Equipm Double Stage Reverse Osmosis Filter System For Pure Water Production0.5 Tons Reverse Osmosis Water Treatment Equipm Double Stage Reverse Osmosis Filter System For Pure Water Production0.5 Tons Reverse Osmosis Water Treatment Equipm Double Stage Reverse Osmosis Filter System For Pure Water Production0.5 Tons Reverse Osmosis Water Treatment Equipm Double Stage Reverse Osmosis Filter System For Pure Water Production0.5 Tons Reverse Osmosis Water Treatment Equipm Double Stage Reverse Osmosis Filter System For Pure Water Production


    Quality 0.5 Tons Reverse Osmosis Water Treatment Equipm Double Stage Reverse Osmosis Filter System For Pure Water Production for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Jingte 'er Environmental Protection Engineering Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)