Sign In | Join Free | My burrillandco.com |
|
Ask Lasest Price | |
Brand Name : | HYJB |
Model Number : | 2T Single Stage |
Price : | negotiable |
Payment Terms : | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability : | 200 sets per month |
Delivery Time : | 7 days |
2T Single-Stage High-End Automatic And Easy To Operate Revise Osmosis Equipment
Working principle:
When osmosis reaches equilibrium, the liquid level on the concentrated solution side will be a certain height higher than that of the dilute solution, that is, a pressure difference is formed, and this pressure difference is the osmotic pressure. The size of the osmotic pressure depends on the inherent properties of the solution, that is, it is related to the type, concentration and temperature of the concentrated solution and has nothing to do with the properties of the semi-permeable film.
Parameter Table:
Model | Water Making Ability | Inlet Caliber | Effluent Caliber | Blowdown alCer | Size(mm) | Power |
YSRO-0.5T | 0.5m3/h | DN20 | DN20 | DN15 | 1500×600×1500 | 1.3kw |
YSRO-1T | 1m3/h | DN25 | DN25 | DN20 | 1700×600×1500 | 2.1kw |
YSRO-2T | 2m3/h | DN32 | DN25 | DN20 | 2500×1000×1950 | 4.4kw |
YSRO-3T | 3m3/h | DN40 | DN32 | DN25 | 2500×1200×2150 | 4.5kw |
YSRO-5T | 5m3/h | DN50 | DN40 | DN32 | 2500×1350×2150 | 7.0kw |
YSRO-8T | 8m3/h | DN50 | DN50 | DN40 | 3500×1500×2150 | 11kw |
YSRO-10T | 10m3/h | DN50 | DN50 | DN40 | 3500×1600×2300 | 15kw |
Key Advantages:
It slows down the change of water quality caused by the fluctuation
of raw water quality, and is beneficial to the stability of water
quality in production, which has a positive effect on the stability
of the quality of demineralized water products.
After setting up the reverse osmosis equipment, the burden of the
terminal microporous membrane filter is greatly reduced, thus
prolonging the life of the terminal microporous membrane filter.
Maintance:
Various operating parameters of RO device are recorded
periodically.
If the equipment runs for a long time, the RO membrane component
will cause fouling, so it is necessary to regularly clean the RO
membrane component chemically. Generally, the working pressure
rises by 10%, the system pressure difference between the inlet
water and the concentrated water rises to 1.5 times the initial
value, the water production drops by 10%, and the water
conductivity rises by 10%. Any one of them is used as a reference
signal for membrane chemical cleaning, even if no abnormalities
occur, in order to better ensure the normal operation of the
system, chemical cleaning can generally be considered every 6
months.
Picture:
![]() |